You are here

ELENA - Wirtschaftsminister plant Nachbesserung

Well, in the last weeks my UPS battery died somewhat. At least the UPS wanted it to be exchanged against a new one. So I ordered a replacement unit and got the battery replaced. The funny thing is now: apcupsd recognize it as fully loaded, but with no remaining Run Time:

As you can see, it's somewhat strange. During loading the battery, apcupsd showed remaining run times of <2 mins, usually <1 min, sometimes 1.2 min or such. But after a reload of the browser, it was quite often <1 min again. Apcaccess is reporting this (excerpt):

[code]DATE : Tue Apr 06 07:21:36 CEST 2010
HOSTNAME : hahn
RELEASE : 3.14.4
VERSION : 3.14.4 (18 May 2008) debian
UPSNAME : BR800I
CABLE : USB Cable
MODEL : Back-UPS BR 800
UPSMODE : Stand Alone
STARTTIME: Mon Apr 05 22:53:00 CEST 2010
STATUS : ONLINE LOWBATT
LINEV : 232.0 Volts
LOADPCT : 41.0 Percent Load Capacity
BCHARGE : 100.0 Percent
TIMELEFT : 0.0 Minutes
MBATTCHG : 20 Percent
MINTIMEL : 5 Minutes
MAXTIME : 0 Seconds
OUTPUTV : 230.0 Volts
LASTXFER : Automatic or explicit self test
SELFTEST : NO
STATFLAG : 0x07000048 Status Flag
BATTDATE : 2001-09-25
FIRMWARE : 9.o4 .I USB FW:o4
APCMODEL : Back-UPS BR 800[/code]

Running a selftest with apctest shows no problem, apparently:

[code]Clearing previous self test result...CLEARED
Initiating self test...INITIATED
Waiting for test to complete...COMPLETED
Result of last self test: PASSED
[/code]

I wonder now how to proceed? Send the battery back? Try a newer version of apcupsd? Contact APC about the issue? Hmmm...

UPDATE:
After connecting the UPS to a laptop with Windows und PowerChute software, apcupsd reports >20 mins remaining time as well. Thanks for all hints & tips!